Patient weight [kg] = 80; Nucleus = "H1"; SmartSelect = "no"; clinical modes = "BODY_QUAD.Complete"; Coil 1 = "Q-Body"; Coil 2 = "None"; FOV RL (mm) = 400; AP (mm) = 350; FH (mm) = 109; Voxel size RL (mm) = 3.125; AP (mm) = 3.125; Slice thickness (mm) = 7; Recon voxel size (mm) = 1.19047618; Fold-over suppression = "no"; Reconstruction matrix = 336; SENSE = "no"; k-t BLAST = "no"; Stacks = 1; type = "parallel"; slices = 7; slice gap = "user defined"; gap (mm) = 10; slice orientation = "transverse"; fold-over direction = "AP"; fat shift direction = "L"; Stack Offc. AP (P=+mm) = 0; RL (L=+mm) = 0; FH (H=+mm) = 0; Ang. AP (deg) = 0; RL (deg) = -0; FH (deg) = -0; Free rotatable = "no"; Minimum number of packages = 1; Slice scan order = "ascend"; Large table movement = "no"; PlanAlign = "no"; REST slabs = 0; Catheter tracking = "no"; Interactive positioning = "no"; Allow table movement = "no"; Patient position = "head first"; orientation = "supine"; Scan type = "Imaging"; Scan mode = "MS"; technique = "FFE"; Contrast enhancement = "no"; Acquisition mode = "cartesian"; Fast Imaging mode = "none"; Echoes = 12; partial echo = "no"; shifted echo = "no"; TE first = "user defined"; (ms) = 1.20000005; echospacing = 1.2000; flyback = "no"; Flip angle (deg) = 20; TR = "user defined"; (ms) = 120; Halfscan = "no"; Water-fat shift = "user defined"; (pixels) = 0.0790000036; Shim = "default"; mDIXON = "no"; Fat suppression = "no"; Water suppression = "no"; MTC = "no"; Research prepulse = "no"; Diffusion mode = "no"; Elastography mode = "no"; SAR mode = "high"; B1 mode = "default"; SAR Patient data = "auto"; PNS mode = "moderate"; Gradient mode = "maximum"; SofTone mode = "no"; Cardiac synchronization = "no"; Heart rate > 250 bpm = "no"; Respiratory compensation = "breath hold"; Breath hold mode = "expiration"; Max slices per breath hold = 10; User def. breath hold dur. = "no"; Navigator respiratory comp = "no"; Flow compensation = "no"; Temporal slice spacing = "default"; fMRI echo stabilisation = "no"; NSA = 1; Angio / Contrast enh. = "no"; Quantitative flow = "no"; Dynamic study = "no"; Arterial Spin labeling = "no"; Preparation phases = "auto"; Interactive F0 = "no"; SmartPlan survey = "no"; B0 field map = "no"; B1 field map = "no"; MIP/MPR = "no"; SWIp = "no"; Images = "M", (3) "no"; Autoview image = "M"; Calculated images = (4) "no"; Reference tissue = "Liver"; Preset window contrast = "intermediate"; Reconstruction mode = "real time"; Save raw data = "no"; Hardcopy protocol = "no"; Image filter = "system default"; Geometry correction = "default"; IF_info_seperator = 1634755923; Total scan duration = "00:13.9"; Rel. SNR = 1; Act. TR/TE1/delta TE (ms) = "120 / 1.20 / 1.20"; Scan time / BH = "00:13.9"; ACQ matrix M x P = "128 x 112"; ACQ voxel MPS (mm) = "3.13 / 3.13 / 7.00"; REC voxel MPS (mm) = "1.19 / 1.18 / 7.00"; Scan percentage (%) = 100; Packages = 1; Min. slice gap (mm) = -0; Max. slices = 10; Act. WFS (pix) / BW (Hz) = "0.079 / 2741.2"; Min. WFS (pix) / Max. BW (Hz) = "0.078 / 2790.2"; Min. TR/TE1/delta TE (ms) = "69 / 1.09 / 0.84"; SAR / local torso = "< 2 %"; Whole body / level = "< 0.1 W/kg / normal"; SED = " 0.0 kJ/kg"; B1+rms = "0.61 uT"; Max B1+rms = "0.61 uT"; PNS / level = "69 % / normal"; dB/dt = "57.5 T/s"; Sound Pressure Level (dB) = 21.981842;